Stay Cable Inspection
Ensure the safety, durability, and load-bearing performance of your cable-supported structures with DYWIDAG’s advanced stay cable inspection services. Over time, aging, environmental exposure, and repeated load cycles can lead to hidden deterioration. DYWIDAG provides certified, non-destructive stay cable inspection solutions that detect both visible and internal damage — helping asset owners manage risk, maintain compliance, and extend service life.
Why stay cable inspection is essential
Stay cables are critical load-bearing elements that directly influence the safety and long-term performance of bridges, stadiums, and other cable-supported structures. Over time, cables are subjected to aging, environmental exposure, and repeated load cycles caused by temperature fluctuations, wind, and traffic.
These influences can lead to progressive and often hidden structural deterioration, including:
Wire or strand breaks caused by corrosion or mechanical damage
Loss of metallic cross-sectional area, reducing load-bearing capacity
Fatigue damage resulting from cyclic loading
Grouting detachment in grouted systems, compromising corrosion protection
Without targeted inspection, these defects can remain undetected until they significantly impact structural safety. Undiagnosed cable deterioration may result in reduced load capacity, unplanned traffic restrictions, costly emergency repairs, or even structural failure.
Regular, professional stay cable inspection enables early detection of both visible and internal damage. This allows asset owners to assess structural risk accurately, plan targeted maintenance measures, and extend the service life of cable-supported structures while maintaining regulatory compliance and traffic safety.


Surface defects in stay cable systems
Different cable systems exhibit distinct surface degradation mechanisms over time. Tailored inspection approaches are therefore required.
Surface defects in full locked cables (FLC)
In full locked cable systems, aging of the outer mechanical or corrosion protection layer may lead to:
Paint detachment and coating failure
Cable bleeding
Corrosion of outer wires
These issues affect not only the visual appearance but also the structural integrity and corrosion protection of the cable.
Surface defects in PE-encased cable systems (PWS & PSS)
Polyethylene-encased systems such as parallel wire systems (PWS) and parallel strand systems (PSS) are primarily affected by:
UV-induced aging of the PE sheath
Cracking or embrittlement of the polyethylene
Loosening of helical fillets due to mechanical damage
In some cases, excessive grout pressure during installation can cause initial micro-damage to the PE casing. When combined with prolonged UV exposure, this can significantly accelerate surface degradation.
Early identification of surface defects allows timely maintenance and helps prevent deeper structural damage.


Why choose DYWIDAG for stay cable inspection?
Decades of cable expertise
With decades of hands-on experience across all cable types, DYWIDAG delivers reliable, efficient, and tailored inspection solutions for complex structural challenges worldwide.
Smart technology meets skilled access
We combine advanced inspection technologies — robotics, magneto-inductive testing, and force measurement - with certified rope access for safe, flexible, and non-invasive inspections.
Deep structural insight
Our non-destructive magneto-inductive inspections detect hidden wire breaks and internal corrosion, enabling early intervention and informed maintenance planning.
From insight to action
Beyond inspection, DYWIDAG identifies suitable repair strategies and delivers complete strengthening and maintenance solutions when required.
From inspection to intervention
Stay cable inspection is often the first step in maintaining long-term structural performance. When defects or early-stage deterioration are identified, DYWIDAG supports asset owners with targeted follow-on services to address specific risks efficiently and sustainably.
Based on inspection findings, DYWIDAG provides integrated solutions including:
Stay cable cleaning to remove contaminants and restore surface condition
Stay cable sheath repair to address cracks, UV damage, and mechanical defects
Stay cable protection systems to enhance long-term corrosion and UV resistance
Damper replacement and retrofit to mitigate vibrations and fatigue-related damage
By combining inspection, assessment, and intervention under one provider, DYWIDAG enables faster decision-making, reduced interface risk, and coordinated maintenance strategies — all aligned with inspection data and asset condition.

Proactively manage risk, ensure compliance, and extend the service life of your assets with DYWIDAG’s stay cable inspection services.
Comprehensive stay cable inspection by DYWIDAG
DYWIDAG delivers a holistic cable inspection approach that addresses both surface-level and internal structural conditions.
Certified visual inspections with rope access
Visual inspections performed by certified bridge inspectors in accordance with DIN 1076
Main inspections typically carried out every six years
Close-up inspections executed using rope access by FISAT Level 3 certified technicians
No scaffolding required, ensuring faster execution and minimal traffic disruption
Robotic cable inspection with panoramic imaging
For long free cable lengths, DYWIDAG deploys robotic inspection systems that:
Capture high-resolution 360° panoramic images
Enable consistent documentation of the entire cable surface
Support precise comparison across inspection cycles
To ensure reliable and repeatable results, imaging is performed in a controlled environment shielded from direct sunlight and supported by artificial lighting. This allows accurate assessment of defect progression over time.
AI-assisted data interpretation supports early identification of potential risks, while certified inspectors validate all findings to ensure dependable condition assessments
Magneto-inductive inspection for hidden damage
Magneto-inductive testing is a powerful complement to visual inspection and is essential for detecting internal stay cable defects that are not visible from the surface.
DYWIDAG offers magneto-inductive inspection of:
Stay cables
Bridge cables
External tendons
This non-destructive testing method magnetizes the entire metallic cross-section of the cable, including the inner core; using permanent magnets, fully compliant with DIN EN 12927. Complete magnetic saturation is essential, as defects cannot be reliably detected without it.
Magneto-inductive inspection reliably detects both internal and external wire breaks, as well as loss of metallic cross-section across the entire cable. These results provide a solid basis for evaluating structural safety, traffic safety, and long-term durability, including an informed estimate of any loss in load-bearing capacity.


Advanced defect localization
Using a combination of induction coils and Hall sensors, the system enables precise three-dimensional localization of defects within the cable. Measurements are repeatable, interference-free, and directly comparable across inspection cycles, ensuring reliable condition assessment over time.
DYWIDAG offers inspection devices for cables up to 315 mm in diameter, suitable for full locked cables, spiral strands, strand ropes, and parallel wire or parallel strand systems. Importantly, inspections are carried out without dismantling HDPE sheathing or existing corrosion protection systems, enabling efficient, non-invasive assessment even in hard-to-reach areas.


Certifications & compliance
Standards-compliant testing
Full magnetization of the entire metallic cross-section in accordance with DIN EN 12927, using CE-conform inspection systems.
Regulatory inspection coverage
Supports DIN 1076 requirements, including mandatory main inspections (Hauptprüfung, HP) every six years.
Mandatory testing for critical systems
Fully compliant with ZTV-ING Part 4.4, where magneto-inductive testing is required for fully locked ropes and strand bundle systems.
Certified specialist execution
Inspections carried out by FISAT-certified rope access technicians, with FISAT being a member of the European Committee for Rope Access (ECRA).
Related Services
Stay cable sheath repair
Essential stay cable sheath and cover repair, and replacement services to keep your cable-stayed structures safe and performing at their best.
Stay Cable Protection
Providing in-depth technical advice and advanced repair technologies customized to your project's unique conditions.
Stay cable detensioning and exchange
Controlled release and reinstallation of stay cables, ensuring structural stability and safety at every stage.
Cable cleaning and surface maintenance
Removal of surface contaminants, to prevent long-term degradation of the sheathing and anchor zones.
Damper replacement and retrofit
DYWIDAG offers inspection, replacement, and retrofit services for stay cable dampers.
Fortalecimiento
Prevenga los daños estructurales y el envejecimiento con una protección especializada contra la corrosión, los rayos UV y los riesgos de incendio.
Cableskin
Protección duradera contra los rayos UV y la corrosión con una interrupción mínima del tráfico.
Related products
Revestimientos de cables Stay
Revestimientos de estancias y amortiguadores que protegen contra las influencias ambientales.
Tirantes
Diseñado para no necesitar mantenimiento.
Soluciones de deshielo
Control del hielo y deshielo de los cables de los tirantes con soluciones pasivas y activas.
Protección contra explosiones
Protección contra explosiones para tirantes: Cumple las directrices de seguridad de puentes de la AASHTO.
Iluminación de cables integrada
Pantallas LED integradas con un impacto mínimo de la carga aerodinámica.
Amortiguadores
Prolongación de la vida útil de sus cables.
Anclaje de horquilla
Admite un diseño estructural de pilón económico.
Sistema de caja de anclaje DYNA Link (solución de asiento)
Solución de sillín con valor añadido.
Sistema DYNA Grip Standard